Introduction - If you have any usage issues, please Google them yourself
(A) design using the bilinear transformation method and the experimental system of a third-order Chebyshev low-pass type Ⅰ digital filter, the sampling frequency Fs = 8KHz, 1DB passband boundary frequency is fp = 2KHz. (B) Bilinear transformation method used to design and use of the experimental system of a third-order Chebyshev type Ⅱ high-pass digital filter, the sampling frequency Fs = 16KHz, stopband boundary frequency fst = 4KHz, As = 20dB.